Login to order online | 800-533-4984 / 801-566-1200

Intran Plus

Intran® Plus is the original transducer-tipped intrauterine pressure catheter (IUPC) preferred by thousands of clinicians for its unrivaled accuracy, safety and reliability.

Product Description
Models
Specifications
Labor & Delivery Brochure
IUPC's & Patient Risk

Intran Plus intrauterine pressure catheter (IUPC).The sensitive, single-use pressure transducer of Intran® Plus is located at the tip of the catheter that is placed inside the uterus. Placement of the transducer inside the uterus ensures that clinical decisions are based on the most accurate contraction frequency, duration, resting tone and peak pressure data.

Poster - "Variable Intrauterine Pressure Catheter (IUPC) Tracings with Two Catheters"

The transducer of Intran® Plus is encapsulated in a soft, blunt boot which prevents partial obstruction by maternal or fetal tissue from affecting the pressure tracing. Coupled with the proprietary SensaFlex™ tubing material of Intran® Plus, the blunt tip allows clinicians to sense and avoid tissue obstructions prior to causing injury. In fact, Intran® Plus has been inserted in over 2 million patients over the last 10 years with no reported patient injuries.*

Brochure - IUPC's & Patient Risk

INSERTION TACTILITY & SAFETY: Intran® Plus is designed with SensaFlex™, a tactile tubing material that is stiff enough to allow insertion while maintaining the pliability necessary to avoid injuries. Combined with the soft, blunt tip of Intran® Plus, SensaFlex™ tubing allows the clinician to sense tissue obstructions prior to causing injury.

TIP SIZE AND SHAPE: Intran® Plus is available in small and regular catheter tip sizes. The small tip (.19" H x .25" W x .90" L) may be slightly easier to introduce through tightly stretched cervical tissues. The regular tip (.25" H x .30" W x 1" L) is also inserted easily but is the optimal size, shape & softness to facilitate safe placement and avoidance of patient tissue injury.

DUAL LUMEN DESIGN & AMNIOINFUSION: The dual lumen design of Intran® Plus allows simultaneous monitoring of uterine contractions and baseline readings while amnioinfusing.

AMNIOTIC FLUID VISUALIZATION: All Intran® Plus configurations are designed with a clear covering over the lumen used for amnioinfusion (Amniolumen). Clinicians may use the clear Amniolumen to assess amniotic fluid return upon IUPC placement or for visualization of fluid during the course of labor. The Amnio View Port option provides a convenient means of amniotic fluid visualization and includes a meconium color scale to facilitate observation of changes in meconium color over time.

RE-ZERO CAPABILITIES: The Intran® Plus IUPC system typically requires a single monitor zeroing procedure. However, a convenient method for re-zeroing the system is provided through the availability of a re-zero switch on the catheter or button on the re-usable cable.

LATEX-FREE: Intran® Plus contains no latex or latex by-products.

* The FDA Manufacturer And User Device Experience (MAUDE) database represents reports of adverse events involving medical devices. The online search allows viewing of CDRH (Center for Devices and Radiological Health) database information about medical devices which may have malfunctioned or caused a death or serious injury. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/search.cfm



Transducer-Tipped IUP Catheters
Model Number Description Unit of Measure Image
IUP-400 Intran® Plus Transducer-Tipped IUPC with Catheter Zero and Amniolumen. * 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-400
IUP-450 Intran® Plus Transducer-Tipped IUPC (small tip) with Catheter Zero and Amniolumen. * 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-450
IUP-500 Intran® Plus Transducer-Tipped IUPC with Catheter Zero, Meconium Viewport and Amniolumen. * 1 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-500
IUP-550 Intran® Plus Transducer-Tipped IUPC (small tip) with Catheter Zero, Meconium Viewport and Amniolumen. * 1 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-550
IUP-600 Intran® Plus Transducer-Tipped IUPC with Zero Switch on Reusable Cable and Amniolumen. * 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-600
IUP-650 Intran® Plus Transducer-Tipped IUPC (small tip) with Zero Switch on Reusable Cable and Amniolumen. * 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-650
IUP-700 Intran® Plus Transducer-Tipped IUPC with Meconium Viewport, Zero Switch on Reusable Cable and Amniolumen. * 1 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-700
IUP-750 Intran® Plus Transducer-Tipped IUPC (small tip) with Meconium Viewport, Zero Switch on Reusable Cable and Amniolumen. * 1 10/BOX Intran® Plus Transducer-Tipped IUPC. Model IUP-750
 
Fluid-Filled IUP Catheters
Model Number Description Unit of Measure Image
IUP-075 78 Inch Double Lumen Fluid-Filled IUPC w/Un-filled 20 cc Syringe. * 10/BOX Fluid-Filled IUPC. Model IUP-075
IUP-005 IUPC Mounting Pad with Strap. * 25/BOX  
 
Reusable Intrauterine Pressure Monitoring Interface Cables
Model Number Description Unit of Measure Image
650-205

Reusable Intrauterine Pressure Monitor Interface Cable for Philips/HP Monitors (not Philips Avalon). *

Use with Intran® Plus Models:
IUP-400, IUP-450, IUP-500, IUP-550

1/EA Intrauterine Pressure Monitor Cable. Model 650-205
650-207

Reusable Intrauterine Pressure Monitor Interface Cable for Philips/HP 8030A (5uv). *

Use with Intran® Plus Models:
IUP-400, IUP-450, IUP-500, IUP-550

1/EA Intrauterine Pressure Monitor Cable. Model 650-207
650-231

Reusable Intrauterine Pressure Monitor Interface Cable for GE/Corometrics Monitors. *

Use with Intran® Plus Models:
IUP-400, IUP-450, IUP-500, IUP-550

1/EA Intrauterine Pressure Monitor Cable. Model 650-231
650-240

Reusable Intrauterine Pressure Monitor Interface Cable for Philips Avalon Monitors. *

Use with Intran® Plus Models:
IUP-400, IUP-450, IUP-500, IUP-550

1/EA Intrauterine Pressure Monitor Cable. Model 650-240
650-240G

Reusable Intrauterine Pressure Monitor Interface Cable for Philips Avalon Monitors
(Cable is gray in color). *

Use with Intran® Plus Models:
IUP-400, IUP-450, IUP-500, IUP-550

1/EA Intrauterine Pressure Monitor Cable. Model 650-240
650-605

Reusable Intrauterine Pressure Monitor Interface Cable with Zero Switch for Philips/HP Monitors (not Philips Avalon). *

Use with Intran® Plus Models:
IUP-600, IUP-650, IUP-700, IUP-750

1/EA Intrauterine Pressure Monitor Cable. Model 650-605
650-631

Reusable Intrauterine Pressure Monitor Interface Cable with Zero Switch for
GE/Corometrics Monitors. *

Use with Intran® Plus Models:
IUP-600, IUP-650, IUP-700, IUP-750

1/EA Intrauterine Pressure Monitor Cable. Model 650-631
650-640

Reusable Intrauterine Pressure Monitor Interface Cable with Zero Switch for Philips Avalon Monitors. *

Use with Intran® Plus Models:
IUP-600, IUP-650, IUP-700, IUP-750

1/EA Intrauterine Pressure Monitor Cable. Model 650-640
 

* Product is CE Marked
1 Patented Product, U.S. Patent # 5,713,351

Sensor Specifications
Transducer Type Silicon diaphragm
Operating Pressure Range -50 to +150mmHg
Sensitivity 5µV/V/mmHg
Non-Linearity and Hysteresis ± 2% of reading or ± 1mmHg, whichever is greater
Sensitivity Thermal Effect ± 0.1 %/° C
Zero Thermal Effect Max. ± 0.3mmHg/° C
Zero Drift With Time < or = 1.0 mmHg/8 hours after 10 minute warm up to body temperature
Leakage Current <10µ A @ 115 VAC rms
Overpressure Protection -400 to +1200mmHg
Operating Temperature 15° C to 40° C
Excitation Voltage and Frequency 2 to 10 VDC; or VAC rms to 5 kHz
 
Catheter Specifications
Catheter Diameter .14 inches
Catheter Length 32.5 inches
Regular Tip Dimensions .25" H x .30" W x 1.00" L
Small Tip Dimensions .19" H x .25" W x .90" L
Amnio Port/Lumen Specifications At a height of 32" the flow rate is greater than 20 ml per minute saline-minimum.
 

 

Login | Ordering | Contact | Disclaimer | Home | © 1999 - 2014 Utah Medical Products, Inc.