UTMD’s gynecology electrodes, UtahLoop® and C-LETZ®, are trusted by women’s health providers to give high confidence of clear margins with minimal removal of healthy cervical tissue, resulting in excellent LETZ specimen histopathology reports.
Product Description
Models
Electrosurgery
Brochure ![]()
UtahLoop®
and C-Letz® Brochure ![]()
DXTender™
Electrode Extender Brochure
Utah
Medical Products' electrosurgical electrodes have been optimally designed
for the specific requirements of specialized electrosurgery. Developed
through exhaustive clinical analysis, the UtahLoop® round loop
electrodes include the Safe-T-Gauge® that provides greater loop
stability and prevents over-excision of healthy cervical tissue. The
'Y' shaped shaft provides additional loop support and increases visibility
during the cutting procedure.
SAFE-T-GAUGE® - The UtahLoop® electrodes have the Safe-T-Gauge®
which allows the clinician to set the maximum depth of excision, preventing
excessive excising of tissue and provides support to the loop wire
for greater strength and stability.
TUNGSTEN WIRE - All loop and needle electrodes utilize high-grade
tungsten wire. Because it retains its mechanical properties at a higher
temperature than stainless steel, tungsten maintains better shape
and wire integrity throughout the excision procedure.
COLOR CODING - Utah Medical Products' electrosurgical electrodes are
individually color coded to help the clinician easily identify electrode
dimensions during selection.
DISPOSABLE - All Utah Medical Products' electrosurgical electrodes
are single use, disposable. This prevents cross-contamination from
patient to patient and ensures the highest level of performance for
each procedure.
STANDARD DIMENSIONS - Our electrodes all utilize the industry standard
3/32" diameter stainless steel shaft which allows easy connection
to standard control pens. In addition, high-dielectric plastic insulation
protects the patient and clinician from electric shock and burn.
EXTERNAL LESION ELECTRODES (5.5cm SHAFT)
Utah Medical Products' short shaft electrodes are ideal for controlled removal of external lesions, providing more utilization of office-based ESU's. Excision of lesions allows for dermatopathology of the specimen, which is not possible with ablative modalities such as cryotherapy.
C-LETZ® CONIZATION ELECTRODES
Current
excisional devices for managing deep endocervical CIN lesions lack
the shape needed to preserve healthy cervical tissue. Cone biopsy
morbidity appears to be related to the total amount of tissue excised,
demonstrating that tissue-sparing excision techniques are important
to improving clinical outcomes. Traditional "straight-wire"
conization electrodes excise an excess of healthy tissue, which may
compromise adequate cervical function. Research has also shown that
CIN involvement in most endocervical glands extends no more than 3.8
mm from the cervical surface. The C-LETZ® conization electrodes
are designed from this research. Their patented contoured electrode
shape removes a constant thickness specimen to ensure adequate removal
of diseased tissue without risking excessive excision of healthy cervical
tissue.
The benefits are clear:
Potentially reduces the possibility of cervical stenosis.
Potentially reduces recurrence and/or progression rates.
Provides simultaneous hemostasis compared to cold knife conization.
DXTENDER™ ELECTRODE EXTENDERS FOR LETZ®
The patent-pending DXTender™ Electrode Extenders provide a unique and effective solution for LETZ procedures.
Cervical
depth varies among patients. LETZ electrode lengths that are appropriate
for one patient will be insufficient to reach another patient's cervix.
A traditional straight extender can provide adequate reach, but the
additional length may cause hand pencil interference with the colposcope
body.
Utah Medical Products, Inc's DXTender™ Electrode Extenders are specially configured to provide positive tactility during the loop excision, yet keep the hand and pencil away from the colposcope and view axis.
| LETZ® Loop Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-T11 | UtahLoop® Round Loop Electrode, 5mm W x 5mm L, 11cm Shaft (Purple). * | 10/BOX | ![]() |
| DLP-S11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 10mm W x 10mm L, 11cm Shaft (Yellow). * | 10/BOX | ![]() |
| DLP-SQ1 | UtahLoop® Cartier Square Loop Electrode, with Safe-T-Gauge®, 10mm W x 10mm L, 11cm Shaft (Orange). * | 10/BOX | ![]() |
| DLP-SQ2 | UtahLoop® Square Loop Electrode, 10mm W x 4mm L, 11cm Shaft
(Brown). * |
10/BOX | ![]() |
| DLP-M11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 15mm W x 12mm L, 11cm Shaft (Green). * | 10/BOX | ![]() |
| DLP-W11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 20mm W x 12mm L, 11cm Shaft (White). * | 10/BOX | ![]() |
| DLP-L11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 20mm W x 15mm L, 11cm Shaft (Blue). * | 10/BOX | ![]() |
| DLP-B11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 25mm W x 8mm L, 11cm Shaft (Tan). * | 10/BOX | ![]() |
| DLP-E11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 25mm W x 22mm L, 11cm Shaft (Canary). * | 10/BOX | ![]() |
| Contoured Conization Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DCE-110 | C-LETZ® Conization Electrode, Large, 15mm Cone Radius x 23mm L. * 1 |
10/BOX | ![]() |
| DCE-115 | C-LETZ® Conization Electrode, Medium, 11mm Cone Radius x 18mm L. * 1 |
10/BOX | ![]() |
| DCE-120 | C-LETZ® Conization Electrode, Ectocervical, 12mm Cone Radius
x 10mm L. * 1 |
10/BOX | ![]() |
| DCE-125 | C-LETZ® Conization Electrode, Small, 9mm Cone Radius x 13mm L. * 1 |
10/BOX | ![]() |
| External Lesion Loop Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-T05 | UtahLoop® External Lesion Round Loop Electrode, 5mm W x 5mm L, 5.5cm Shaft (Purple). * | 10/BOX | ![]() |
| DLP-S05 | UtahLoop® External Lesion Round Loop Electrode, 10mm W x 10mm L, 5.5cm Shaft (Yellow). * | 10/BOX | ![]() |
| DLP-M05 | UtahLoop® External Lesion Round Loop Electrode, 15mm W x 12mm L, 5.5cm Shaft (Green). * | 10/BOX | ![]() |
| DLP-B05 | UtahLoop® External Lesion Round Loop Electrode, 25mm W x 8mm L, 5.5cm Shaft (Tan). * | 10/BOX | ![]() |
| DLP-SQ3 | UtahLoop® External Lesion Square Loop Electrode, 10mm W x 4mm L, 5.5cm Shaft (Pink). * | 10/BOX | ![]() |
| Needle Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-N11 | Macro Needle Electrode, 0.8mm dia x 15mm L, 11cm Shaft (Red). * | 10/BOX | ![]() |
| DLP-U11 | Micro Needle Electrode, 0.2mm dia x 15mm L, 11cm Shaft (Black). * | 10/BOX | ![]() |
| DLP-N05 | External Lesion Macro Needle Electrode, 0.8mm dia x 5mm L, 5.5cm Shaft (Red). * | 10/BOX | ![]() |
| DLP-U05 | External Lesion Micro Needle Electrode, 0.2mm dia x 5mm L, 5.5cm Shaft (Black). * | 10/BOX | ![]() |
| Ball Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DBL-311 | UtahBall® Ball Electrode, 3mm dia, 11cm Shaft (Black). * | 10/BOX | ![]() |
| DBL-511 | UtahBall® Ball Electrode, 5mm dia, 11cm Shaft (Red). * | 10/BOX | ![]() |
| DBL-505 | UtahBall® External Lesion Ball Electrode, 5mm dia, 5.5cm Shaft (Red). * | 10/BOX | ![]() |
| Electrode Extenders | |||
| Model Number | Description | Unit of Measure | Image |
| DXT-S06 | DXTender™ Electrode Extender, small. * | 10/BOX | ![]() |
| DXT-L09 | DXTender™ Electrode Extender, large. * | 10/BOX | ![]() |
| DLP-X10 | Electrode Extender, straight 11cm shaft. * | 10/BOX | ![]() |
| Electrode Sampler Kits | |||
| Model Number | Description | Unit of Measure | |
| DLS-100 | Electrode Sampler Kit #1, includes 1 ea. of DBL-311, DBL-511, DLP-S11, DLP-W11, and 2 ea. DLP-M11. * | 1/EA | |
| DLS-200 | Electrode Sampler Kit #2, includes 2 ea. of DBL-311, DBL-511, DLP-S11; and 3 ea. of DLP-M11 and DLP-W11. * | 1/EA | |
| DLS-300 | Electrode Sampler Kit #3, includes 1 ea. of DBL-311, DBL-511, DLP-B11, DLP-L11, DLP-M11, DLP-S11, DLP-T11, DLP-W11, and DLP-SQ1. * | 1/EA | |
* Product is CE Marked
1 Patented Product, U.S. Patent # 5,951,550