UTMD’s patented gynecology electrodes, UtahLoop® and C-LETZ®, are trusted by women’s health providers to give high confidence of clear margins with minimal removal of healthy cervical tissue, resulting in excellent LETZ specimen histopathology reports.
Product Description
Models
Electrosurgery
Brochure
UtahLoop®
and C-Letz® Brochure
Utah
Medical Products' electrosurgical electrodes have been optimally designed
for the specific requirements of specialized electrosurgery. Developed
through exhaustive clinical analysis, the UtahLoop® round loop
electrodes include the patented Safe-T-Gauge® that provides greater
loop stability and prevents over-excision of healthy cervical tissue.
The 'Y' shaped shaft provides additional loop support and increases
visibility during the cutting procedure.
Loop electrodes have the patented Safe-T-Gauge® which allows the
clinician to set the maximum depth of excision.
All loop and needle electrodes utilize high grade tungsten wire.
Color coded for ease in identification.
Single-use and disposable, preventing cross-contamination and ensuring
consistent performance on every procedure.
Electrodes have an industry-standard 3/32" shaft diameter, and
are compatible with all electrosurgical systems.
Safe-T-Gauge®
The UtahLoop® electrodes have the patented Safe-T-Gauge® which allows the clinician to set the maximum depth of excision, preventing excessive excising of tissue and provides support to the loop wire for greater strength and stability.
Tungsten Wire
All loop and needle electrodes utilize high-grade tungsten wire. Because it retains its mechanical properties at a higher temperature than stainless steel, tungsten maintains better shape and wire integrity throughout the excision procedure.
Color Coding
Utah Medical Products' electrosurgical electrodes are individually color coded to help the clinician easily identify electrode dimensions during selection.
Disposable
All Utah Medical Products' electrosurgical electrodes are single use, disposable. This prevents cross-contamination from patient to patient and ensures the highest level of performance for each procedure.
Standard Dimensions
Our electrodes all utilize the industry standard 3/32" diameter stainless steel shaft which allows easy connection to standard control pens. In addition, high-dielectric plastic insulation protects the patient and clinician from electric shock and burn.
EXTERNAL LESION ELECTRODES (5.5cm SHAFT)
Utah Medical Products' short shaft electrodes are ideal for controlled removal of external lesions, providing more utilization of office-based ESU's. Excision of lesions allows for dermatopathology of the specimen, which is not possible with ablative modalities such as cryotherapy.
C-LETZ® CONIZATION ELECTRODES
Current
excisional devices for managing deep endocervical CIN lesions lack
the shape needed to preserve healthy cervical tissue. Cone biopsy
morbidity appears to be related to the total amount of tissue excised,
demonstrating that tissue-sparing excision techniques are important
to improving clinical outcomes. Traditional "straight-wire"
conization electrodes excise an excess of healthy tissue, which may
compromise adequate cervical function. Research has also shown that
CIN involvement in most endocervical glands extends no more than 3.8
mm from the cervical surface. The C-LETZ® conization electrodes
are designed from this research. Their patented contoured electrode
shape removes a constant thickness specimen to ensure adequate removal
of diseased tissue without risking excessive excision of healthy cervical
tissue.
The benefits are clear:
Potentially reduces the possibility of cervical stenosis.
Potentially reduces recurrence and/or progression rates.
Provides simultaneous hemostasis compared to cold knife conization.
| LETZ® Loop Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-T11 | UtahLoop® Round Loop Electrode, 5mm W x 5mm L, 11cm Shaft (Purple). * | 10/BOX | ![]() |
| DLP-S11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 10mm W x 10mm L, 11cm Shaft (Yellow). * 1 | 10/BOX | ![]() |
| DLP-SQ1 | UtahLoop® Cartier Square Loop Electrode, with Safe-T-Gauge®, 10mm W x 10mm L, 11cm Shaft (Orange). * 1 | 10/BOX | ![]() |
| DLP-SQ2 | UtahLoop® Square Loop Electrode, 10mm W x 4mm L, 11cm Shaft
(Brown). * |
10/BOX | ![]() |
| DLP-M11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 15mm W x 12mm L, 11cm Shaft (Green). * 1 | 10/BOX | ![]() |
| DLP-W11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 20mm W x 12mm L, 11cm Shaft (White). * 1 | 10/BOX | ![]() |
| DLP-L11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 20mm W x 15mm L, 11cm Shaft (Blue). * 1 | 10/BOX | ![]() |
| DLP-B11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 25mm W x 8mm L, 11cm Shaft (Tan). * 1 | 10/BOX | ![]() |
| DLP-E11 | UtahLoop® Round Loop Electrode, with Safe-T-Gauge®, 25mm W x 22mm L, 11cm Shaft (Canary). * 1 | 10/BOX | ![]() |
| Contoured Conization Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DCE-110 | C-LETZ® Conization Electrode, Large, 15mm Cone Radius x 23mm L. * 2 |
10/BOX | ![]() |
| DCE-115 | C-LETZ® Conization Electrode, Medium, 11mm Cone Radius x 18mm L. * 2 |
10/BOX | ![]() |
| DCE-120 | C-LETZ® Conization Electrode, Ectocervical, 12mm Cone Radius
x 10mm L. * 2 |
10/BOX | ![]() |
| DCE-125 | C-LETZ® Conization Electrode, Small, 9mm Cone Radius x 13mm L. * 2 |
10/BOX | ![]() |
| External Lesion Loop Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-T05 | UtahLoop® External Lesion Round Loop Electrode, 5mm W x 5mm L, 5.5cm Shaft (Purple). * | 10/BOX | ![]() |
| DLP-S05 | UtahLoop® External Lesion Round Loop Electrode, 10mm W x 10mm L, 5.5cm Shaft (Yellow). * | 10/BOX | ![]() |
| DLP-M05 | UtahLoop® External Lesion Round Loop Electrode, 15mm W x 12mm L, 5.5cm Shaft (Green). * | 10/BOX | ![]() |
| DLP-B05 | UtahLoop® External Lesion Round Loop Electrode, 25mm W x 8mm L, 5.5cm Shaft (Tan). * | 10/BOX | ![]() |
| DLP-SQ3 | UtahLoop® External Lesion Square Loop Electrode, 10mm W x 4mm L, 5.5cm Shaft (Pink). * | 10/BOX | ![]() |
| Needle Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-N11 | Macro Needle Electrode, 0.8mm dia x 15mm L, 11cm Shaft (Red). * | 10/BOX | ![]() |
| DLP-U11 | Micro Needle Electrode, 0.2mm dia x 15mm L, 11cm Shaft (Black). * | 10/BOX | ![]() |
| DLP-N05 | External Lesion Macro Needle Electrode, 0.8mm dia x 5mm L, 5.5cm Shaft (Red). * | 10/BOX | ![]() |
| DLP-U05 | External Lesion Micro Needle Electrode, 0.2mm dia x 5mm L, 5.5cm Shaft (Black). * | 10/BOX | ![]() |
| Ball Electrodes | |||
| Model Number | Description | Unit of Measure | Image |
| DBL-311 | UtahBall® Ball Electrode, 3mm dia, 11cm Shaft (Black). * | 10/BOX | ![]() |
| DBL-511 | UtahBall® Ball Electrode, 5mm dia, 11cm Shaft (Red). * | 10/BOX | ![]() |
| DBL-505 | UtahBall® External Lesion Ball Electrode, 5mm dia, 5.5cm Shaft (Red). * | 10/BOX | ![]() |
| Electrode Extender | |||
| Model Number | Description | Unit of Measure | Image |
| DLP-X10 | Electrode Extender, 11cm Shaft(Blue). * |
10/BOX | ![]() |
| Electrode Sampler Kits | |||
| Model Number | Description | Unit of Measure | |
| DLS-100 | Electrode Sampler Kit #1, includes 1 ea. of DBL-311, DBL-511, DLP-S11, DLP-W11, and 2 ea. DLP-M11. * | 1/EA | |
| DLS-200 | Electrode Sampler Kit #2, includes 2 ea. of DBL-311, DBL-511, DLP-S11; and 3 ea. of DLP-M11 and DLP-W11. * | 1/EA | |
| DLS-300 | Electrode Sampler Kit #3, includes 1 ea. of DBL-311, DBL-511, DLP-B11, DLP-L11, DLP-M11, DLP-S11, DLP-T11, DLP-W11, and DLP-SQ1. * | 1/EA | |
* Product is CE Marked
1 Patented Product, U.S. Patent # 5,324,288
2 Patented Product, U.S. Patent # 5,951,550